Thông tin chi tiết sản phẩm:
Thanh toán:
|
Shell Color: | Black | Item: | Power Distribution Unit |
---|---|---|---|
Product Installation Mode: | Bracket installation | Rated Voltage Current: | 230VAC 32A |
Szie: | 1650*85*41mm | Grade: | Grade B |
Output Rated Voltage: | 220VAC、250VAC、380VAC、-48VDC、240VDC | Application: | outdoor telecom cabinet |
Cable Mounting: | Up input | Lightning Proof: | Grade B, single phase, 60-100KA L+N, 2P |
Number Of Outlets: | 8 | Input Type: | AC single-phase, AC three-phase, DC 48v |
Color: | Black | Product Model: | RDK-IP08M16 |
Way: | 8 way, 12 way ,16way | ||
Làm nổi bật: | Intelligent Power Distribution Unit 8 outlet,16A 250VAC PDU with RS-485,8 outlet power distribution unit 16A |
Intelligent Power Distribution Unit Outlet Breaking Capacity 16A 250VAC RS-485 port, support cascade connection horizontal installation customized protocol
Four functions of intelligent PDU
Energy monitoring function
Capable of providing rich energy use, efficiency, and data center environmental monitoring functions, intelligent PDUs can measure the input voltage and current of each circuit, and calculate the power used in watts or kilowatts. It can also be used to calculate total energy usage and let data center operators know if they need to add additional PDUs.
Environmental monitoring function
The new generation of intelligent PDUs can monitor and manage the environment through the existing data center LAN. Intelligent PDU set sensor. Intelligent PDUs can track environmental factors and issue timely warnings. In addition, administrators can compare environmental data with power consumption data to determine server power consumption and verify the effectiveness of in-rack temperature control measures.
PDU access and network functions
Intelligent PDUs can be connected to PDUs over a LAN and managed flexibly through a Web browser or command line interface (CLI). This gives administrators easy access to data and real-time monitoring.
Centralized management and data analysis and statistics
Intelligent PDUs can be managed and accessed by a centralized management platform to achieve group management, permission management, data report generation, microenvironment prediction, and so on for all PDUs in the data center.
Features of intelligent PDU products
Intelligent PDU products completely break the constraints of interval and region, and can complete the security monitoring, security early warning, and intelligent management of the power supply in the computer room through the local area network and wide area network in any place in the world.
As an important end unit of power supply equipment, intelligent PDU improves the stability and reliability of the system.
Intelligent PDUs can monitor and manage the operating status through Ethernet interfaces or RS-485 interfaces, such as the total current, port output current, voltage, power factor, port switch status, and temperature and humidity of PDUs. This can better manage related power devices and ensure the stability of the power supply system.
Intelligent PDU users can also set the safety valve value of the total load by themselves. When the total current of the PDU exceeds the set threshold, power accident warning is generated to prevent the load of the PDU from exceeding the allowable range, which further improves the power safety level of the equipment room.
Energy saving is another value of intelligent PDU products. Intelligent PDUs can obtain more information and control functions, so that users can know the current power consumption of equipment and racks at any time. This helps to determine how to manage and control power distribution intelligently and efficiently.
The wide application of intelligent PDUs can also greatly reduce labor costs and improve operation efficiency.
Intelligent power management solutions allow users to more accurately and effectively monitor power consumption, equipment operation control, and monitoring of the machine room environment.
Unit monitoring and control PDU
On the basis of monitoring the total power of the PDU input, real-time monitoring and control of each output outlet are realized. Authorized users can safely remotely control the opening, closing, or restarting of each or a group of output outlets, and conduct real-time early warning.
Monitoring content
Total power, input voltage, total input current, each output current, environment (temperature and humidity, access control, flooding, smoke, infrared).
Range
90-275VAC (Resolution: 1V; Accuracy: soil 1%+1 word), 0.1~63A (Resolution: 0.1A; Accuracy: ±1%+1 word).
Unit switch
Control on and off of each output, and power on and off sequentially.
Access Port | Illustration | Parameter | Note |
---|---|---|---|
Serial port | Via RS-485 monitor access | RS-485 port, support cascade connection | |
Sensor port | Sensors access | Support environment monitoring | |
Secondary development | RS485 | Customized protocol | |
Software upgrade | Manage software load | Support manage software upgrade | |
Control | |||
Control each outlets on/off | Each outlet breaking capacity | 16A 250VAC | |
Powered on/off in sequence | The interval of sequential power off time: 1s, Sequential power on 1~250s, user-defined | ||
Power status holding | When PDU restart power, Each outlet will remain the status before | ||
Monitor | |||
Monitor the input voltage | Resolution: 1V, Accuracy: ±1%+1 digit, Meter range: 90~350V | ||
Monitor the input current | Resolution: 0.1A, Accuracy: ±1%+1 digit, Meter range: 0.1~40A | ||
Monitor the total electric energy | Resolution: 0.1KWh, Accuracy: 1 grade | ||
Monitor the input active power | Resolution: 1W, Accuracy: ±1%+1 digit | ||
Monitor the input power factor | Resolution: 0.001, Accuracy: ±1%+3 digit | ||
Monitor each socket's current | Resolution: 0.1A, Accuracy: ±1%+1 digit, Meter range: 0.1~20A | ||
Monitor each socket's electric energy | Resolution: 0.1KWh, Accuracy: 1 grade | ||
Monitor each socket's active power | Resolution: 1W, Accuracy: ±1%+1 digit | ||
Monitor each socket's power factor | Resolution: 0.001, Accuracy: ±1%+3 digit | ||
Monitor Environment Temperature | Resolution: 1°C, Accuracy: ±1%+1 digit, Meter range: -30~100°C | Optional | |
Monitor Environment Humidity | Resolution: 1%, Accuracy: ±1%+1 digit, Meter range: 01~99% | Optional | |
Alarm Limit Setting | Input current/voltage limit | Auto identify limit rationality |
Người liên hệ: Ms. Fiona Liang